4 NX-148E-RF LCD Touchpad w ith Receiver Installation Instructions
9. To program remaining transmitters, repeat steps 6 to 8.
10. To exit program mode, press EXIT EXIT.
Transmitter options
Door/window transmitter settings
To set features 4 (Input option 1) and 5 (Input option 2) for
door/window transmitters, do the following:
To disable the transmitter’s internal reed s witches, turn on
feature 4.
Turn on feature 5 for a normally closed (N/C) external
contact; turn off feature 5 for a normally open (N/O)
external contact.
Wireless smoke detector settings
To set feature 4 (Input option 1) for wireless smoke detectors,
do the following:
For wireless smoke detectors with tamper switches, turn
feature 4 on to enable the tamper feature.
For wireless smoke detectors without tamper switches,
turn feature 4 off (disabled).
Note: Feature 4 must be off (disabled) when using
wireless smoke detectors without tamper switches.
4-button keyfob settings
Keyfob functions 1 and 2 can be used to control relays,
outputs, or X10 devices. See Locations 593 and 594 in Error!
Reference source not found..
To set features 4 (Input option 1) and 5 (Input option 2) for 4-
button keyfobs, do the following:
To change the Light button to keyfob function 1, turn on
feature 4.
To change the Star button to keyfob function 2, turn on
feature 5.
Partition settings for keyfobs
To program partition settings, do the following:
1. Enter * 8 at the touchpad.
2. Enter your program code (factory default is 9 7 1 3).
3. Enter the device number and press # (see Table 2).
4. Enter the location number and press #. For example, enter
401 # to enter location 401, segment 1. Press * for
segment 2.
5. Press the touchpad button that corresponds to the keyfob
partition number you want to change. The number will be
displayed for the keyfob partitions. Press the partition
number to toggle the partition on and off.
6. To continue programming keyfob transmitter partition
settings, repeat steps 4 to 8.
7. To exit program mode, press EXIT EXIT.
Transmitter supervision windows
To change the transmitter supervision windows, do the
following:
1. Enter * 8 at the touchpad.
2. Enter your program code (factory default is 9 7 1 3).
3. Enter the device number and press # (see Table 2).
4. Enter 595 # to enter location 595, segment 1.
5. Enter the new normal supervision time (0 to 255) and
press *. If you enter 0, it will set the normal supervision
time to 256 hours
Caution: Do not set the normal or fire supervision windows to
1 hour. This causes false trouble reports from all learned
wireless transmitters.
1. Enter the new fire supervision time (0 to 255) and press *.
If you enter 0, it will set the fire supervision window to 256
hours.
2. Enter the new short supervision time (up to 30 minutes).
The short supervision setting prevents arming if a
transmitter has not checked in within the set time. This
applies only to specific countries outside the U.S. Check
the control panel installation manual to determine if this
setting is available. Enter a number higher than 30 (the
default value is 40) to disable the feature.
3. Press * to save any changes. The panel is now waiting for
the next location entry.
Note: If you press # it does not save changes to the
current segment, but it does save changes made in
previous segments.
4. To exit program mode, press EXIT EXIT.
Delete transmitters
This procedure makes the receiver ignore a transmitter but
does not remove transmitter identification from the receiver’s
memory. The transmitter can be reactivated later or a new one
can be learned into the zone.
To delete a transmitter, do the following:
1. Enter * 8 at the touchpad.
2. Enter your program code (factory default is 9 7 1 3).
3. Enter the device numb er and press # (see Table 2).
Page view 3