Interlogix T-100 User Manual

Browse online or download User Manual for Safety Interlogix T-100. Interlogix T-100 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
TruPortal
Series
T-100 Model Reader
Technical support
For assistance with this product, refer to this document and any other
documentation provided. If you still have questions, you may contact technical
support during normal business hours (Monday through Friday, excluding
holidays, between 8 a.m. and 8 p.m. Eastern Standard Time.)
See http://www.interlogix.com/customer-support.
U.S.
1-855-286-8889, option 2
Canada
1-855-286-8889, option 2
Latin America
1-561-998-6114
Web site: http://www.interlogix.com
© 25JUL13, United Technologies Corporation
Interlogix is part of UTC Climate, Controls & Security, a unit of United
Technologies Corporation. All rights reserved.
Interlogix
3211 Progress Drive, Lincolnton, NC 28092, USA
Description
The T-100 card reader is a card serial number reader
compatible with the following 125 kHz Proximity
technologies:
CASI ProxLite
®
•HID
®
Proximity
Mounting the reader
1. Find a suitable mounting position on the door frame
or wall.
2. Drill two vertical mounting holes 2.25” (57.2 mm)
apart on the mounting surface of the door frame or
wall.
Figure 1. Dimensions
3. Drill one 1.00” (25.4 mm) diameter hole in wall for the
pigtail wire connection.
4. Follow the Cable Connection Chart to connect the
reader to the field panel.
5. Mount the base plate to the wall using the supplied
screws.
6. Hook the top of the reader case to the top of the base
plate and press into place.
Figure 2. Base plate, reader case, and top cover
7. Install the supplied screw in the base of the reader.
8. Snap the cover on the top of the case.
Connecting the cable
1. The readers are supplied with an 8-conductor cable
pigtail with drain wire. Connect the pigtail to the host
panel. Use the Cable Connection Chart (below) to
correctly match the color of each wire.
2. Use a DC power source between 5-16 VDC.
3. Connect the reader’s drain wire to the cable shield.
Connect shield wires at the field panel.
front view
side
view
1.75”
[44.5mm]
1.0”
[
25.4mm]
4.20
[106.7mm]
Color Signal
Black Ground
Blue Beeper
Brown Red LED Control
Green Data 0
Orange Green LED Control
Red 5 to 16 VDC
White Data 1
Drain Shield Ground
Page view 0
1 2

Summary of Contents

Page 1 - TruPortal

TruPortal™ Series T-100 Model ReaderTechnical supportFor assistance with this product, refer to this document and any other documentation provided. If

Page 2 - Ordering information

Testing the reader1. Power up the reader. Verify the power-on self test LED/beep sequence:- green LED flashes; two short beeps- yellow LED flashes; th

Comments to this Manuals

No comments