NX-148E-RF LCD Touchpad w ith Receiver Installation Instructions 9
Silent exit (EXIT)
To silence the exit beeps during exit delay (while the system is
disarmed), do the following:
1. Enter * EXIT.
2. Enter your user code.
3. To exit, press #.
Reference tables
Table 9. Service menu messages
A short circuit of a pow er supply has
occurred.
Open circuit on the bell or siren circuit.
(Optional) The box tamper circuit has
activated.
The phone line connected to the control is
not operating properly.
The control made an unsuccessful attempt
to communicate a message to the central
station.
A short to ground has been detected on a
control circuit.
Your system has lost total pow er and needs
the clock reset.
The main pow er to the system is off.
The standby battery is low .
A auxiliary reporting device (i.e. NX-580E,
NX-582E, etc.) has failed to communicate.
A short circuit of an expansion devices
pow er supply has occurred.
The main pow er to an expansion pow er
supply is off.
An expansion pow er supply has a low
battery.
A box containing an expansion device has
been opened.
A radio receiver is being jammed.
An expansion device or touchpad is not
reporting to the control panel.
An expansion device has detected trouble
on the bell or siren circuit.
A zone is tampered. Press * to identify the
tampered zone.
Zone low battery,
press *
A w ireless device has a low battery. Press *
to identify the zone.
A w ireless or multiplexed zone device is not
reporting to the control. Press * to identify
the zone.
A zone is experiencing trouble. Press * to
identify the zone.
Table 10. Log messages
Zone lost - A w ireless multiplexed zone
device is not reporting to the control.
The control has been armed or disarmed
w ith a Duress code.
Manual fire - Touchpad Fire has been
activated.
Auxiliary 2 - Touchpad Medical has been
activated.
Touchpad Panic has been activated.
Touchpad Tamper - The touchpad tamper
has been activated.
Box Tamper - The box tamper circuit has
been activated.
AC failure has been detected.
Over current - A short circuit of a pow er
supply has occurred.
Siren tamper - A siren or speaker tamper
has been detected.
Telephone fault - A telephone fault or
tamper has been detected.
Expansion trouble - An expansion device or
touchpad is not reporting to the control.
Reports, user number, date, time and
partition of opening.
Reports, user number, date, time and
partition of closing.
Exit error - Entry/exit zone w as faulted when
the exit delay expired.
Recent close - An alarm occurred within 5
minutes of the control being armed.
Automatic test - Sending a communicator
test at a specified interval.
Start programming - Local Programming
has started.
End programming -Local programming has
ended.
Start dow nload - Dow nload session has
started.
End dow nload - Dow nload session has
ended.
Cancel w as initiated w ithin 5 minutes of an
alarm.
Ground fault - A short to ground has been
detected.