NX-148E-RF LCD Touchpad w ith Receiver Installation Instructions 7
Assign user authority (6)
To assign user authority levels, you must have authority over
the assigned partitions. To assign user authority, do the
following:
1. Enter * 6.
2. Enter your master code.
3. Enter the user number.
4. Use keys 1 (yes) and 0 (no) to assign authorities when
prompted, or press * to move to the next prompt.
5. Assign the partitions for the user.
6. To return to step 3 and program another user code, press
*.
7. To exit, press #.
Note: Retain at least one code with access rights to all
partitions to allow adding future users.
Reset function (7)
The system must be disarmed to reset the smoke detectors,
zone troubles, and zone tampers. To reset, do the following:
1. Enter * 7.
2. To exit, press #.
Note: If the keypad begins beeping, the reset didnt
execute properly. Enter your code to silence the touchpad.
Wait a few minutes and repeat the reset.
Log review (90)
The control panel has an event log of at least the last 185
events along with the date, time, and partition where the event
occurred. To review the log, do the following:
1. Enter * 90.
2. Enter your program or master code.
3. Press to view events from newest to oldest, or press
to view events from oldest to newest.
4. To exit, press #.
The following screen sample shows an opening in Partition 3
on September 25th at 5:57 pm by user 75. The * indicates that
this event is not programmed to be reported to the central
monitoring station.
Open 75
9/25 17:57 P3*
Table 10 lists some of the possible event log messages.
Adjust view/brightness of LCD (91)
To adjust the view and brightness of the LCD display, do the
following:
1. Enter * 91.
2. Enter your master code.
3. Press or to raise or lower the view angle and press * to
save the selection.
4. Press or to brighten or dim the LCD and press * to
save the selection.
5. To exit, press #.
Program custom messages (92)
When you program custom messages:
If an NX-148 (non-E) is installed on the same system, it
must be used to program the text. All messages are
transferred to other touchpads when you exit this mode.
Use the * 94 (Set touchpad number and partition)
function to set the touchpad numbers prior to
programming custom messages.
If a touchpad is added after messages are programmed,
you need to either program all messages in it, or enter
custom message programming on an existing touchpad
and press 1 #, #, #, EXIT.
Refer to * 93 (Set touchpad options) to prevent
overwriting the custom message.
To program custom messages, do the following:
1. Enter * 92.
2. Enter your program code.
3. The LCD will prompt you to enter the message number
followed by #. Zones 1 through 192 custom messages are
message numbers 1 to 192 respectively.
Message 193 = Custom message top line.
Message 194 = Custom message bottom line.
Message 195 = Shutdown message top line.
Message 196 = Shutdown message bottom line.
Enter the message number and press #. The display will
show the zone number on the top line and a description on
the bottom line. Refer to Table 7 for information on editing
character data.
4. Press EXIT to exit