EN 13 TruVision Analog PTZ Camera
Address settings
DIP switch SW1 is used to set the address of the PTZ dome. See
Table 1 below to set the PTZ camera address to a specific number.
Table 1: PTZ camera addresses
Address
1 2 3 4 5 6 7 8
0 OFF OFF OFF OFF OFF OFF OFF OFF
1 ON OFF OFF OFF OFF OFF OFF OFF
255 ON ON ON ON ON ON ON ON
Baud rate settings
Use positions 1, 2, and 3 of DIP switch SW2 to set the baud rate of the
PTZ dome. The values to select are 2400 bps, 4800 bps, 9600 bps,
19200 bps and 38400 bps. The default baud rate is 2400 bps. See
Table 2 below.
Table 2: Baud rate values
Baud rate 1 2 3
2400 ON OFF OFF
4800 OFF ON OFF
9600 ON ON OFF
19200 OFF OFF ON
38400 ON OFF ON
Protocol Settings
Use positions 4, 5, and 6 of DIP switch SW2 to set the communication
protocols of the dome. See Table 3 below.
Table 3: Protocol values
Protocol 4 5 6
Interlogix-485 OFF OFF OFF
PELCO-D ON OFF OFF
PELCO OFF ON OFF
Reserved Others