PROGRAMMING THE LED KEYPADS
This section describes how to program the address of each keypad as well as the options that are available. The
address of the keypad is important because this is how the panel supervises the keypads. The factory default for the
Master code is [1]-[2]-[3]-[4] when using a 4-digit code or [1]-[2]-[3]-[4]-[5]-[6] for a 6-digit code. The factory
default for the "Go To Program" code is [9]-[7]-[1]-[3] for a 4-digit code or [9]-[7]-[1]-[3]-[0]-[0] for a 6-digit
code.
[r]-[9]-[3] Set keypad options
1. Enter [r]-[9]-[3] [program code]. The "Service" LED will flash.
2. LEDs 1-8 can now be toggled on/off to enable/disable the following functions:
3. After enabling/disabling the desired functions, press [r]
LED
KEYPAD FEATURE ENABLED
1
RESERVED. DO NOT PROGRAM THIS AT ALL!
2
Enable Silent Keypad option - silences the entry/exit sounder & chime only.
3
Enable Ding Dong sound for Chime - If off, chime will be a single tone. (See location 40, page 18)
4
Enable Keypress Silence option - silences the pulsing keypad sounder for 5 seconds when a key is
pressed
5
Enable Armed Status Suppression - will not allow the keypad to display faulted or bypassed zones when
the system is armed
6
Enable Panic, Fire, Medical Beeptone - will sound a short beep to verify that the keypress was accepted
7
Suppresses the "Service" LED - will not allow the "Service" LED to illuminate for any reason. If there is a
system trouble, pressing [r]-[2] will still show the service menu. (NOTE: For UL installations, the Service
LED shall not be suppressed)
8
RESERVED. This LED should always be “OFF”.
[r]-[9]-[4] Set keypad number
1. Enter [r]-[9]-[4]-[program code]. The "Service" LED and the "Instant" LED will flash.
2. Enter the keypad number (1-8).
3. Press [r]. The "Instant" LED will illuminate steady and the"Service" LED will remain flashing.
4. Enter [1]. The keypad will automatically exit this mode at this time.
[r]-[9]-[5] Set elapsed increments since last autotest
1. Enter [r]-[9]-[5]-[program code]. The "Service" LED will flash.
2. Enter [100's digit]
3. Enter [10's digit]
4. Enter [1's digit]
5. Press [#] to save and exit.
[r]-[9]-[6] Set system date
1. Enter [r]-[9]-[6]-[master code]. The "Service" LED will flash.
2. Enter [day of week (1=Sun)]
3. Enter [month 10's digit]
4. Enter [month 1's digit]
5. Enter [day 10's digit]
6. Enter [day 1's digit]
7. Enter [year 10's digit]
8. Enter [year 1's digit]
[r]-[9]-[7] Set system clock
1. Enter [r]-[9]-[7]-[master code]. The "Service" LED will flash.
2. Enter [hour 10's digit]
3. Enter [hour 1's digit]
4. Enter [minutes 10's digit]
5. Enter [minutes 1's digit]
Page view 9