Simon XT Installation Guide
'HVFULSWLRQ
This is the Installation Guide for the Simon XT control panel
(models 600-1054-95R-11 and 600-1054-95R-11-CN).
The system can monitor up to 40 sensors including:
• Door/Window sensor (60-670)
• Indoor motion sensor (60-639)
• Outdoor motion sensor (60-639)
• Remote handheld touchpad (60-671)
• Two-Way Talking Touchpad/Touch Screen (60-924)
Contact your UTC Fire & Security representative for a more
co
mplete list.
&DXWLRQ Do not use outdoor motion sensors for intrusion
protection
Table 1 below describes the recommended sensor groups.
7DEOH5HFRPPHQGHGVHQVRUJURXSV
'HYLFH 5HFRPPHQGHG VH
QVRU JURXS
Indoor motion sensor 17
a
Outdoor motion sensor 25 (chime only group)
b
Entry/exit door 10
Interior door 14
Window sensor 13
Smoke sensor 26
c
Key fob 01
ELM key fob 01
Remote handheld touchpad 01
Two-Way Talking Touchpad/Touch
Screen
01
b
CO alarm 34
b
Freeze sensor 29
b
Water sensor 38
b
Personal help button 01
Property/asset management 43
b d
a. Not certified as a primary protection circuit for UL-listed
systems and is for supplementary use only.
b. Has not been investigated by UL.
c. Re
quired for UL-listed residential fire alarm applications.
d. W
e recommend you use this group type in combination
wit
h a Two-Way Talking Touch Screen.
1RWH Additional devices employing UTCFS 80 Bit Enhanced
Protocol have not been investigated for use in a UL Listed
installation.
,QVWDOODWLRQ
Tabs at the top of the panel secure and release the front cover
and the chassis. The plastic hinges on the panel bottom allow the
cover and chassis to swing down and out of the way.
7RPRXQWWKHSDQHORQDZDOO
1. Choose a panel location.
2. Run all necessary power, phone, siren, and hardwired
contact wires to the
desired panel location.
When choosing the AC outlet location for the AC power
transformer, make sure the outlet is not controlled by a
switch or that it is not part of a ground fault circuit interrupt
(GFCI).
3. Hold the panel against the wall and mark the mounting hole
locations with a pencil.
4. Mount the back piece to the wall through the two horizontally
centered mounting holes near the top and bottom using the
supplied mounting hardware. Use wall anchors if no studs are
present.
&RQQHFWLQJKDUGZLUHGGHYLFHV
The panel has five screw terminals, two battery terminals, and
two telephone connections. The screw terminals connect the AC
power, sirens, and or hardwired detectors.
)LJXUH:LULQJWHUPLQDOV
HW1 I/O
HW1&2
DC out
HW2 in
9VAC in
9VAC in
Battery +
Battery -
Program sensors and devices before you install them. Follow the
instructions in “Sensors” on page 4 to add the sensors to panel
memory.
The HW1 I/O terminal is dual purpose and can be used for either
siren or hardwired contact connections. The HW2 in terminal is an
input only.
,QWHULRUVLUHQ V
From the factory, the HW1 I/O input (terminal 1) is set up for
interior siren operation (status and alarm sounds). The HW1&2 DC
out (terminal 2) provides the positive (+) voltage.
© 2011 UTC Fire & Security. All rights reserved. 1 / 8 P/N 466-2398 • REV B • ISS 09JAN13