Interlogix Simon XT REV B Installation Manual User Manual

Browse online or download User Manual for Control panel Interlogix Simon XT REV B Installation Manual. Interlogix Simon XT REV B Installation Manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 8
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Simon XT Installation Guide
'HVFULSWLRQ
This is the Installation Guide for the Simon XT control panel
(models 600-1054-95R-11 and 600-1054-95R-11-CN).
The system can monitor up to 40 sensors including:
Door/Window sensor (60-670)
Indoor motion sensor (60-639)
Outdoor motion sensor (60-639)
Remote handheld touchpad (60-671)
Two-Way Talking Touchpad/Touch Screen (60-924)
Contact your UTC Fire & Security representative for a more
co
mplete list.
&DXWLRQ Do not use outdoor motion sensors for intrusion
protection
Table 1 below describes the recommended sensor groups.
7DEOH5HFRPPHQGHGVHQVRUJURXSV
'HYLFH 5HFRPPHQGHG VH
QVRU JURXS
Indoor motion sensor 17
a
Outdoor motion sensor 25 (chime only group)
b
Entry/exit door 10
Interior door 14
Window sensor 13
Smoke sensor 26
c
Key fob 01
ELM key fob 01
Remote handheld touchpad 01
Two-Way Talking Touchpad/Touch
Screen
01
b
CO alarm 34
b
Freeze sensor 29
b
Water sensor 38
b
Personal help button 01
Property/asset management 43
b d
a. Not certified as a primary protection circuit for UL-listed
systems and is for supplementary use only.
b. Has not been investigated by UL.
c. Re
quired for UL-listed residential fire alarm applications.
d. W
e recommend you use this group type in combination
wit
h a Two-Way Talking Touch Screen.
1RWH Additional devices employing UTCFS 80 Bit Enhanced
Protocol have not been investigated for use in a UL Listed
installation.
,QVWDOODWLRQ
Tabs at the top of the panel secure and release the front cover
and the chassis. The plastic hinges on the panel bottom allow the
cover and chassis to swing down and out of the way.
7RPRXQWWKHSDQHORQDZDOO
1. Choose a panel location.
2. Run all necessary power, phone, siren, and hardwired
contact wires to the
desired panel location.
When choosing the AC outlet location for the AC power
transformer, make sure the outlet is not controlled by a
switch or that it is not part of a ground fault circuit interrupt
(GFCI).
3. Hold the panel against the wall and mark the mounting hole
locations with a pencil.
4. Mount the back piece to the wall through the two horizontally
centered mounting holes near the top and bottom using the
supplied mounting hardware. Use wall anchors if no studs are
present.
&RQQHFWLQJKDUGZLUHGGHYLFHV
The panel has five screw terminals, two battery terminals, and
two telephone connections. The screw terminals connect the AC
power, sirens, and or hardwired detectors.
)LJXUH:LULQJWHUPLQDOV
HW1 I/O
HW1&2
DC out
HW2 in
9VAC in
9VAC in
Battery +
Battery -
Program sensors and devices before you install them. Follow the
instructions in “Sensorson page 4 to add the sensors to panel
memory.
The HW1 I/O terminal is dual purpose and can be used for either
siren or hardwired contact connections. The HW2 in terminal is an
input only.
,QWHULRUVLUHQ V
From the factory, the HW1 I/O input (terminal 1) is set up for
interior siren operation (status and alarm sounds). The HW1&2 DC
out (terminal 2) provides the positive (+) voltage.
© 2011 UTC Fire & Security. All rights reserved. 1 / 8 P/N 466-2398 • REV B • ISS 09JAN13
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - Simon XT Installation Guide

Simon XT Installation Guide 'HVFULSWLRQThis is the Installation Guide for the Simon XT control panel (models 600-1054-95R-11 and 600-1054-95R-1

Page 2 - :LULQJSKRQHOLQHV

1RWHThe total current available from the HW1&2 DC out terminal is 250 mA at up to 120ºF (49ºC). A 24-hour battery standby for UL requirements wi

Page 3 - 3URJUDPPLQJ

:LULQJWKHSRZHUWUDQVIRUPHU Connect the power transformer to the two 9 VAC in terminals (4 and 5) on the panel. Do not plug in the transformer at thi

Page 4

Table 3 below shows the top menu structure. To see all of the possible options, refer to the Simon XT Installation Manual. 7DEOH7RSPHQXVWUXFWXUH

Page 5 - 6HQVRUWHVWLQJ

'HYLFH 7R SURJUDP Freeze and water sensor Trip the tamper or press and hold the button on the top of the sensor (cover removed) until the control

Page 6 - 5HJXODWRU\LQIRUPDWLRQ

1RWHRefer to specific sensor installation instructions for complete operation and testing details. &HQWUDOVWDWLRQFRPPXQLFDWLRQ After performi

Page 7

6,$V\VWHPUHTXLUHPHQWVSIA system requirements are the same as those described for a UL-listed basic system, plus if multiple annunciations are requi

Page 8 - &RQWDFWLQIRUPDWLRQ

&RQWDFWLQIRUPDWLRQ UTC Fire & Security Americas Corporation, Inc. 8985 Town Center Parkway Bradenton, FL 34202 T + 1 888 437 3287 F + 1 888

Comments to this Manuals

No comments