NX-148E LCD Keypad
18
This display is reflecting all 8 areas are Ready,
and Area 5 is disarmed. NOTE: If a number is
flashing on the Armed line, that area is armed
Instant. If a number is flashing on the Ready
line, that area is ready to be Force Armed.
If ALL areas are disarmed and ready to arm,
this display will appear on the LCD screen.
ARMING AND DISARMING MULTIPLE PARTITIONS
To arm/disarm multiple partitions, enter a code that has arm/disarm authority for ALL
of the partitions to be armed/disarmed. The following display will appear on the LCD
screen.
The numbers on the top line represent the
disarmed areas to which this code has access.
The numbers on the bottom line represent the
areas that are armed. Refer to the following
table for possible conditions.
LCD DISPLAY FOR AREA
TOP LINE OVER BOTTOM LINE
CONDITION
Blank
Blank
Area Not used or Authorized
Dash (-)
Dash (-)
Area Not Ready
Flashing Area #
Dash (-)
Area Ready to Force Arm
Dash (-)
Flashing Area #
Area Armed Instant
Area #
Dash (-)
Area Disarmed & Ready to Arm
Dash (-)
Area #
Area is Armed
To disarm all of these areas, press .
To arm all of these areas, press .
To toggle a single area between the armed and disarmed conditions, press
[][Area number]. For example: If Area 4 is armed, [] [4] will disarm Area 4.
If Area 4 is disarmed, [] [4] will arm it.
Press [STAY] during the exit delay to bypass all interior zones in the exit delay.
To control the individual areas, refer to the following section.
Ready 12345678
Armed 1234-678
System Ready
Type code to arm
12-45-78 Disarm º
--3 67- Arm º