Concord Express User Instructions P/N 466-1667 • REV • OCT12 J
Concord Express User Instructions 5 Getting to Know Your Security System This manual describes how to operate your system. It describes basic armin
6 Concord Express User Instructions Your system may also use wireless, handheld touchpads that can be carried from room to room. Keychain touchpad
Concord Express User Instructions 7 Communicating with the Panel Your system can be set up to communicate with you through: • Status beeps • Alarm
8 Concord Express User Instructions Status Beeps Status beeps from touchpads or sirens sound when there is a change in the current status of the sys
Concord Express User Instructions 9 The arming indicator will be off when the system is disarmed. READY Note: Any time you notice that the ready lig
10 Concord Express User Instructions Level 1—OFF Use Level 1 when intrusion detection is not necessary. For example, on an active Saturday mornin
Concord Express User Instructions 11 5. If leaving the premises, exit through a designated delay door immediately. Arming Level 3—AWAY At other
12 Concord Express User Instructions To use Quick Arm: • Increase the arming level by simply pressing 2 or 3 at any touchpad. • Decreasing the arm
Concord Express User Instructions 13 Chime-On-Close The Chime-On-Close feature works like the regular Chime feature, but in addition to the double
Copyright © 2012 UTC Fire & Security Americas Corporation, Inc. Interlogix is part of UTC Climate Controls & Security, a unit of Unite
14 Concord Express User Instructions central monitoring station or a numeric pager to send reports. You can have your installer program this delay
Concord Express User Instructions 15 • The Entry Delay is a period of time long enough to let you unlock a designated delay door and get to a touc
16 Concord Express User Instructions Extended Delay In some situations, additional time is needed to arm or disarm the system from, for example, a p
Concord Express User Instructions 17 Touchpads display an arming message, such as “Armed to STAY No Delay” or “ARMED TO AWAY NO DELAY,” for exampl
18 Concord Express User Instructions Bypassing a Sensor Directly Use this method if the system is armed and you would like to open a window without
Concord Express User Instructions 19 2. Arm your system to the desired level. The touchpad emits protest beeps and displays “PROTEST,” because of
20 Concord Express User Instructions Short System Status A Short Status indicates the current arming level, sensor status (whether open or bypassed
Concord Express User Instructions 21 Rapid Beeps Panic Alarms Panic alarms are easily activated from any touchpad to quickly alert the central moni
22 Concord Express User Instructions To activate an Auxiliary panic alarm from a touchpad: Press and hold the Auxiliary button(s) for 2 seconds. Sir
Concord Express User Instructions 23 Access Codes The system requires a valid access code before it will process most commands. The Appendix A User
Notices FCC Notices FCC Part 15 Information to the User Changes or modifications not expressly approved by UTC Fire & Security can void the us
24 Concord Express User Instructions Programming Access Codes User codes can be given certain attributes which determine whether the user can bypas
Concord Express User Instructions 25 Assigning the System Test Attribute System Tests is a user code attribute that allows the user to perform syste
26 Concord Express User Instructions To set the system date: 1. Enter the programming menus by pressing 9 + System Master Code. 2. Press 01. 3.
Concord Express User Instructions 27 To enable Arming Always Silent: Note: Exit Delay is doubled when you enable Silent Arming. 1. Enter the prog
28 Concord Express User Instructions 2 + # Medium 3 + # High 4. Press * + 4 + # to exit the programming menus. After dimming the display, pressing
Concord Express User Instructions 29 Although all three types of information can be reported on your pager, your pager service determines how the
30 Concord Express User Instructions 698 Keyswitch sensor used 699 System armed itself because it is being serviced or powered-up Account Number i
Concord Express User Instructions 31 See “Notification by Pager” on page 28 for more information on paging reports. Latchkey Paging The Latchkey p
32 Concord Express User Instructions Appendix A: User Sheets” on page 40 to see if the No Activity feature is currently available to you and the du
Concord Express User Instructions 33 Press B to display the system number. For example, “N – nnnnnnn,” or “SYSTEM NUMBER * nnnnnnn.” Press B to
If this equipment causes harm to the telephone network, the telephone company may temporarily disconnect your service. If possible, you will be
34 Concord Express User Instructions minutes remain to the Test Mode time, the system sounds a short beep every 60 seconds. 2. Use the procedures l
Concord Express User Instructions 35 • If the phone test is unsuccessful, the touchpad displays “SYSTEM PHONE TEST ALARM,” then, “MEMORY,” and
36 Concord Express User Instructions Door/window sensor Open the secured door or window. • Zones nn OK • SENSOR nn OK Smoke detector Press and
Concord Express User Instructions 37 Silencing Trouble Beeps If possible, correct the situation which is causing the trouble beeps. If this is not p
38 Concord Express User Instructions Table 4: Causes of trouble beeps Touchpad feedback after pressing * Trouble condition AC POWER FAILURE The
Concord Express User Instructions 39 PHONE FAILURE TROUBLE The system can’t communicate with the central monitoring station. The system tries to
40 Concord Express User Instructions Appendix A: User Sheets Appendix A contains specific information about the setup of your system. The User She
Concord Express User Instructions 41 21 22 23 24 User Codes The tables below provide space for you to record user codes and the attributes o
42 Concord Express User Instructions Touchpad Information Status beeps and Key beeps are programmable by the installer. The Silent Arming feature
Concord Express User Instructions 43 Keychain Touchpad 3 Keychain Touchpad 4 Accidental Smoke and Fire Alarms To silence the alarms and reset the
The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used
44 Concord Express User Instructions _____________________________________________________________________ _________________________________________
Concord Express User Instructions 45 Keyswitch Arming Yes. I can use a key to arm the system. The switch is located: ______________________________
46 Concord Express User Instructions • Yes. If there is no activity in my system for ____ hours (1-42, default 24), the system will send a No Activ
Concord Express User Instructions 47 Floor Plan Example Figure 2 below shows an example of a multilevel floor plan. Use it as a guide and draw your
48 Concord Express User Instructions Floor plan for your home or business Alarm System Limitations Not even the most advanced alarm system can gua
Concord Express User Instructions 49 • If intruders have the technical means of bypassing, jamming, or disconnecting any or all parts of the syste
50 Concord Express User Instructions Appendix C: Programming Your System You can program the following items on your system: • System time and dat
Concord Express User Instructions 51 To change or assign a user access code: Note: The system will not accept the same code for two different users
52 Concord Express User Instructions Using Programming Shortcuts A programming shortcut is a number that gets you to a particular spot in the prog
Concord Express User Instructions 53 2. User programming tasks. 3. The sequence of keystrokes to take you to the task. 4. Specific information to
54 Concord Express User Instructions Direct Bypassing for User 04 1 0 0 4 1 1 (Off) or 2 (On) System Tests for User 04 1 0 0 4 2 Change User code
Concord Express User Instructions 55 Direct Bypassing for User 11 1 0 1 1 1 1 (Off) or 2 (On) System Tests for User 11 1 0 1 1 2 Change User code
56 Concord Express User Instructions Notes
Concord Express User Instructions i Content Notices 3 FCC Notices 3 Canada Notice 4 Getting to Know Your Security System 5 Overview 5 Comm
ii Concord Express User Instructions Was the Bypass Successful? 19 Checking the Status of Your System 19 Short System Status 20 Full System S
Concord Express User Instructions iii Appendix A: User Sheets 40 Account Number 40 System Sensors 40 User Codes 41 Touchpad Information 4
Comments to this Manuals