Interlogix NS2503-24P/2C User Manual User Manual

Browse online or download User Manual for Accessories communication Interlogix NS2503-24P/2C User Manual. Interlogix NS2503-24P/2C User Manual User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 197
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews

Summary of Contents

Page 1 - IFS NS2503-24P/2C User

P/N 1072568 • REV 00.07 • ISS 31JAN13 IFS NS2503-24P/2C User Manual

Page 2

NS2503-24P/2C User Manual 10How to Use This Manual This User Manual is structured as follows: Section 2, INSTALLATION The section explains the functi

Page 3 - TABLE OF CONTENTS

NS2503-24P/2C User Manual 100Spanning Tree Protocol Theory The Spanning Tree protocol can be used to detect and disable network loops, and to provid

Page 4

NS2503-24P/2C User Manual 101 Bridge Protocol Data Units For STP to arrive at a stable network topology, the following information is used:  The uni

Page 5

NS2503-24P/2C User Manual 102 Each port on a switch using STP exists is in one of the following five states:  Blocking – the port is blocked from fo

Page 6

NS2503-24P/2C User Manual 103 Illustration of STP A simple illustration of three switches connected in a loop is depicted in the below diagram. In thi

Page 7

NS2503-24P/2C User Manual 104 Figure 4-8-3: After Applying the STA Rules STP Parameters STP Operation Levels The Switch allows for two levels of op

Page 8 - Introduction

NS2503-24P/2C User Manual 105 The following are the user-configurable STP parameters for the port or port group level: Variable Description Defaul

Page 9

NS2503-24P/2C User Manual 106 Figure 4-8-4: STP System Configuration Interface Screenshot The page includes the following fields: Object Description

Page 10 - How to Use This Manual

NS2503-24P/2C User Manual 107 Follow the rule as below to configure the MAX Age, Hello Time, and Forward Delay Time. 2 x (Forward Delay Time value

Page 11 - Product Features

NS2503-24P/2C User Manual 108 The page includes the following fields: Object Description  Priority The bridge identifier of the root bridge. It is

Page 12

NS2503-24P/2C User Manual 109 Port Configuration This web page provides the port configuration interface for STP. You can assign higher or lower prior

Page 13 - Product Specification

NS2503-24P/2C User Manual 11 Product Features  Physical Port  24-Port 10/100Base-TX Fast Ethernet ports with IEEE 802.3af / IEEE 802.3at PoE injec

Page 14

NS2503-24P/2C User Manual 110 Admin P2P: The rapid state transitions possible within STP are dependent upon whether the port concerned can only be con

Page 15 - INSTALLATION

NS2503-24P/2C User Manual 111 DHCP Relay & Option 82 The Relay Agent Information option (Option82) is inserted by the DHCP relay agent when forwar

Page 16 - LED Indications

NS2503-24P/2C User Manual 112 Figure 4-9-1: DHCP Relay and Option 82 Function Interface Screenshot The page includes the following fields: Object D

Page 17

NS2503-24P/2C User Manual 113LLDP Link Layer Discovery Protocol (LLDP) is used to discover basic information about neighboring devices on the local b

Page 18 - Switch Rear Panel

NS2503-24P/2C User Manual 114Per Port Configuration This page allows the user to inspect and configure the current LLDP port settings, the web screen

Page 19 - Install the Switch

NS2503-24P/2C User Manual 115Access Control List The Access Control List (ACL) is a concept in computer security used to enforce privilege separation

Page 20 - Rack Mounting

NS2503-24P/2C User Manual 116 The page includes the following fields:  IPv4 ACL Object Description Default Vaule Group ID 1 ~ 200 Action Permi

Page 21

NS2503-24P/2C User Manual 117  Non-IPv4 ACL In ※Packet Type / Binding box Non-IPv4 should be selected. Object Description Default Vaule Group ID

Page 22

NS2503-24P/2C User Manual 118 Users Configuration It is allowed to configure the Managed Switch to authenticate users logging into the system for ma

Page 23 - SWITCH MANAGEMENT

NS2503-24P/2C User Manual 119 Add / Edit User This page configures a user – add, edit or delete user. Figure 4-12-2: Add New User Configuration In

Page 24 - Management Access Overview

NS2503-24P/2C User Manual 12  Cisco ether-channel (Static Trunk)  Spanning Tree Protocol - STP, IEEE 802.1D (Classic Spanning Tree Protocol) - M

Page 25 - Web Management

NS2503-24P/2C User Manual 120 If you forget the password, please press the “Reset” button located on the front panel of the Managed Switch over 10

Page 26 - Administration Console

NS2503-24P/2C User Manual 121MAC Limit MAC limit allows users to set a maximum number of MAC addresses to be stored in the MAC address table. The MAC

Page 27

NS2503-24P/2C User Manual 122 MAC Limit Port Status This table displays current MAC Limit status of each port. Figure 4-13-2: MAC Limit – MAC Limit P

Page 28 - Protocols

NS2503-24P/2C User Manual 123 802.1X Configuration 802.1x is an IEEE authentication specification which prevents the client from accessing a wireless

Page 29 - Web-Based Management

NS2503-24P/2C User Manual 124 initial identity/request frame followed by one or more requests for authentication information). Upon receipt of the fra

Page 30 - Requirements

NS2503-24P/2C User Manual 125 If the link state of a port transitions from up to down, or if an EAPOL-logoff frame is received, the port returns to th

Page 31

NS2503-24P/2C User Manual 126 The page includes the following fields: Object Description IEEE 802.1x Protocol: Enable or disable 802.1x protocol. Ra

Page 32 - Main WEB PAGE

NS2503-24P/2C User Manual 127 802.1x Port Configuration In this page, you can select the specific port and configure the authorization state. The stat

Page 33

NS2503-24P/2C User Manual 128 Misc Configuration In this page, you can change the default configuration for the 802.1x standard: Figure 4-14-6: 802.1

Page 34

NS2503-24P/2C User Manual 129QoS Configuration Understand QoS Quality of Service (QoS) is an advanced traffic prioritization feature that allows y

Page 35 - System Information

NS2503-24P/2C User Manual 13 Product Specification Product NS2503-24P/2C 24-Port 10/100Mbps + 2 Gigabit TP / SFP Managed 802.3at PoE Switch Hardware

Page 36 - Misc Config

NS2503-24P/2C User Manual 130 QoS Configuration QoS settings allow customization of packet priority in order to facilitate delivery of data traffic th

Page 37

NS2503-24P/2C User Manual 131The table includes the following fields: Object Description First Come First Service The sequence of packets sent is b

Page 38

NS2503-24P/2C User Manual 132 QoS PerPort Configuration Configure the priority level for each port. With the Priority Type selected as Port-based, thi

Page 39

NS2503-24P/2C User Manual 133 TOS/DSCP TOS/DSCP priority is obtained through a 6-bit Type-of-Service (TOS) or Differentiated Service Code Point (DSCP)

Page 40 - Console Port Info

NS2503-24P/2C User Manual 134 TOS/DSCP Configuration The TOS/DSCP page provides fields for defining output queue to specific DSCP fields. When TCP/IP’

Page 41 - SNMP Configuration

NS2503-24P/2C User Manual 135 Figure 4-15-6 : QoS Configuration – TOS/DSCP Port Status Interface Screenshot The table includes the following fields:

Page 42

NS2503-24P/2C User Manual 136 Power over Ethernet Providing up to 24 PoE, in-line power interface, the NS2503-24P/2C PoE Switch can easily build a

Page 43

NS2503-24P/2C User Manual 137 NS2503-24P/2C Power Management In a power over Ethernet system, operating power is applied from a power source (PSU-powe

Page 44 - SNMPv3 Groups

NS2503-24P/2C User Manual 138 The page includes the following fields: Object Description System PoE Admin Mode Allows user enable or disable PoE func

Page 45 - SNMPv3 View

NS2503-24P/2C User Manual 139 Device class Class 0 is the default for PDs. However, to improve power management at the PSE, the PD may opt to provide

Page 46 - SNMPv3 Access

NS2503-24P/2C User Manual 14 Auto-negotiation 10/100/1000Mbps full and half duplex mode selection Flow Control disable / enable Port Status Display ea

Page 47

NS2503-24P/2C User Manual 140 PD Classifications A PD may be classified by the PSE based on the classification information provided by the PD. The

Page 48 - SNMP V3 usm-user

NS2503-24P/2C User Manual 141 PoE Schedule PoE Schedule allows user to scheduling PoE power supply. User has to define when system supplies PoE power

Page 49 - Syslog Setting

NS2503-24P/2C User Manual 142 Figure 4-16-4: PoE Configuration Interface

Page 50 - System Log

NS2503-24P/2C User Manual 143 CONSOLE MANAGEMENT The Managed Switch is equipped with a RS-232 DB9 connector as default. And support telnet management

Page 51 - SNTP Setting

NS2503-24P/2C User Manual 144 Configure IP address The Managed Switch is shipped with the following default IP address. IP Address : 192.168.0.100 S

Page 52 - Firmware Upgrade

NS2503-24P/2C User Manual 145 Configure IP address 1. On “Switch(config)# ” prompt, enter the following command and press <Enter>. As show in

Page 53 - HTTP Firmware Upgrade

NS2503-24P/2C User Manual 146 Commands Level The following table lists the CLI commands and description. Modes Access Method Prompt Exit Method A

Page 54 - Configuration Backup

NS2503-24P/2C User Manual 147 COMMAND LINE INTERFACE Operation Notice To enter the “configuration” mode, you need to be in the privileged mode, and

Page 55 - TFTP Backup Configuration

NS2503-24P/2C User Manual 148 System Commands show running-config Description: Display the running configuration of the switch. copy running-config s

Page 56 - System Reboot

NS2503-24P/2C User Manual 149 Switch Static Configuration Port Configuration and show status port state Turn the port state on or off. Syntax: port s

Page 57

NS2503-24P/2C User Manual 15INSTALLATION This section describes the hardware features and installation of the Managed Switch on the desktop or rack

Page 58

NS2503-24P/2C User Manual 150 <port-list> specifies the ports to be set. If not entered, all ports are set. port jumboframe Description: Set po

Page 59 - Rate Control

NS2503-24P/2C User Manual 151 ---------------------------------------------------------------------- TxGoodPkt: 0 TxBadPkt: 0 RxGoodPkt: 0 RxBadPkt: 0

Page 60 - Port Status

NS2503-24P/2C User Manual 152 Trunk Configuration Trunk allows the switch to combine ports so that they function like a single high-speed link. It can

Page 61 - Port Statistics

NS2503-24P/2C User Manual 153 lacp system-priority Description: Set LACP system priority. Syntax: lacp system-priority <1..65535> Parameters: &l

Page 62 - Port Sniffer

NS2503-24P/2C User Manual 154 VLAN Configuration Virtual LANs A Virtual LAN (VLAN) is a logical network group that limits the broadcast domain. It al

Page 63

NS2503-24P/2C User Manual 155 The Managed Switch support both Port-based VLAN and Tag-based (802.1Q) VLAN modes. The default configuration is tag-base

Page 64 - Protect Port

NS2503-24P/2C User Manual 156Advanced 802.1Q VLAN Configuration Ingress filters configuration When a packet was received on a port, you can govern th

Page 65 - Remote Ping

NS2503-24P/2C User Manual 157 This VLAN entry has four members (from port1 to port4) and all members are untagged. no vlan Description: Delete VLAN en

Page 66 - VLAN configuration

NS2503-24P/2C User Manual 158 Switch(config)# show vlan pvid Port | PVID -----------+------- Port1 | 1 Port2 | 1 Port3 | 1 Port4 | 1 Port

Page 67 -  Default VLANs

NS2503-24P/2C User Manual 159 Misc Configuration no mac-age-time Description: Set MAC address age-out time. Syntax: [no] mac-age-time Enable or disab

Page 68 - Static VLAN Configuration

NS2503-24P/2C User Manual 16 Reset button On the left side of the front panel, the reset button is designed for rebooting the Managed Switch withou

Page 69 - Port-based VLAN

NS2503-24P/2C User Manual 160 no hostname Reset the switch name to factory default setting. [no] password Description: Set or remove username and

Page 70

NS2503-24P/2C User Manual 161 If you set this command, the switch will reboot. show dhcp Description: show dhcp enable/disable. Reboot switch boot

Page 71 - 802.1Q VLAN

NS2503-24P/2C User Manual 162 Restore Configure File copy tftp <running-config | flash> Description: Retrieve configuration from the TFTP serve

Page 72 - VLAN Group Configuration

NS2503-24P/2C User Manual 163 Port Mirroring Configuration Port monitoring is a feature to redirect the traffic occurred on every port to a designated

Page 73

NS2503-24P/2C User Manual 164 Quality of Service There are four transmission queues with different priorities in the Managed Switch: Highest, SecHigh,

Page 74

NS2503-24P/2C User Manual 165 e.g. Switch(config)# show qos QoS configurations: QoS mode: weighted round robin Highest weight: 8 Second High weight: 4

Page 75 - VLAN Filter

NS2503-24P/2C User Manual 166 00:03:63:F7:80:7F | 1 | Dynamic | 9 show mac-address table static Description: Display static MAC address table

Page 76 - GVRP VLAN

NS2503-24P/2C User Manual 167 STP/MSTP Commands [no] spanning-tree Description: Enable or disable spanning-tree. spanning-tree forward-delay Descript

Page 77 - GVRP Setting

NS2503-24P/2C User Manual 168 show spanning-tree Description: Show spanning-tree information. show spanning-tree port Description: Show spanning tree

Page 78 - GVRP Table

NS2503-24P/2C User Manual 169 <1-200000000> specifies port path cost. <port-list> specifies the ports to be set. Null means all ports. sp

Page 79 - Q-in-Q VLAN

NS2503-24P/2C User Manual 17  Per 10/100Mbps port, PoE interfaces (Port-1 to Por-24) LED Color Function Illuminates: To indicate the link through

Page 80 - Q-in-Q Port Setting

NS2503-24P/2C User Manual 170 spanning-tree mst <0-15> vlan [<vlan-list>] Description: Set MSTI to map VLAN list. Syntax: spanning-tree m

Page 81 -  To configure QinQ Port

NS2503-24P/2C User Manual 171 show spanning-tree mst <0-15> Description: Show MST instance information. Syntax: show spanning-tree mst <0-15

Page 82 - Trunking

NS2503-24P/2C User Manual 172 SNMP Any Network Management running the simple Network Management Protocol (SNMP) can be management the switch. System

Page 83 - Aggregator setting

NS2503-24P/2C User Manual 173 Parameters: <community-str> specifies the community string. e.g. snmp community read-all-only public no snmp comm

Page 84 - Aggregator Information

NS2503-24P/2C User Manual 174 igmp fastleave Description: Enable/disable IGMP snooping fast leave. If enable, switch will fast delete member who sen

Page 85 -  Switch 1 configuration

NS2503-24P/2C User Manual 175 802.1x Protocol dot1x Description: Enable or disable 802.1x. Syntax: [no] dot1x radius-server host Description: Set

Page 86 -  Switch 2 configuration

NS2503-24P/2C User Manual 176 dot1x timeout supplicant Description: Set 802.1x supplicant timeout (default: 30 seconds) Syntax: dot1x timeout supplic

Page 87

NS2503-24P/2C User Manual 177 Access Control List Packets can be forwarded or dropped by ACL rules include Ipv4 or non-Ipv4. The Managed Switch can be

Page 88 - State Activity

NS2503-24P/2C User Manual 178 <1-220> specifies the group id. (permit|deny) specifies the action. permit: permit packet cross switch; deny: drop

Page 89 - Forwarding and Filtering

NS2503-24P/2C User Manual 179 Binding Let device that has specific IP address and MAC address can use network. We can set specific IP address, MAC add

Page 90 - Static MAC Table

NS2503-24P/2C User Manual 18 Switch Rear Panel The rear panel of the Managed Switch indicates an AC inlet power socket, which works with an input powe

Page 91 - MAC Filtering

NS2503-24P/2C User Manual 180 Power over Ethernet Commands show poe Show System Power over Ethernet information show poe status Show PoE port infor

Page 92 - IGMP Snooping

NS2503-24P/2C User Manual 181 show poe status Description: Show per PoE port information Command Level Global Configuration Syntax: show poe status

Page 93

NS2503-24P/2C User Manual 182 Configure PoE -- System poe limit-mode Description: Configure System PoE power limit mode information Command Level Glo

Page 94

NS2503-24P/2C User Manual 183poe admin-mode Description: Configure System PoE Admin mode information Command Level Global Configuration Syntax: poe

Page 95

NS2503-24P/2C User Manual 184poe temperature Description: Configure System PoE Temperature Threshold information Command Level Global Configuration

Page 96 - IGMP Configuration

NS2503-24P/2C User Manual 185 Configure PoE -- Port poe enable Description: Enabling or disabling the port POE injects function. Command Level: G

Page 97

NS2503-24P/2C User Manual 186poe priority Description: Set port priority for the power supply management. Command Level: Global Configuration Sy

Page 98 - Static Multicast Table

NS2503-24P/2C User Manual 187 poe power-mode Description: Set poe power mode for the power supply management Command Level Global Configuration Sy

Page 99

NS2503-24P/2C User Manual 188 SWITCH OPERATION Address Table The Switch is implemented with an address table. This address table composed of many entr

Page 100 - Spanning Tree Protocol

NS2503-24P/2C User Manual 189 POWER OVER ETHERNET OVERVIEW What is PoE? Based on the global standard IEEE 802.3af, PoE is a technology for wired Ethe

Page 101 - NS2503-24P/2C User Manual

NS2503-24P/2C User Manual 19 Install the Switch This section describes how to install the Managed Switch and make connections to it. Please read the f

Page 102

NS2503-24P/2C User Manual 190 Figure 2 - Power Supplied over the Data Pins When to install PoE? Consider the following scenarios:  • You're p

Page 103 - Illustration of STP

NS2503-24P/2C User Manual 191 Stages of powering up a PoE link Stage Action Volts specified per 802.3af Volts managedby chipset Detection Measure w

Page 104 - STP Parameters

NS2503-24P/2C User Manual 192 DC Disconnect DC Disconnect detection involves measurement of current. Naturally, a disconnected PD stops consuming curr

Page 105 - STP System Configuration

NS2503-24P/2C User Manual 193 TROUBLE SHOOTING This chapter contains information to help you solve problems. If the Ethernet Switch is not functionin

Page 106

NS2503-24P/2C User Manual 194 Appendix A—RJ-45 Pin Assignment Switch's RJ-45 Pin Assignments 1000Mbps, 1000Base T Contact MDI MDI-X 1 BI_DA+

Page 107 -  Root Bridge Information

NS2503-24P/2C User Manual 195 The standard cable, RJ-45 pin assignment The standard RJ-45 receptacle/connector There are 8 wires on a standard UTP

Page 108

NS2503-24P/2C User Manual 196 APPENDIX B: Local User Access Level Table Model NS2503-24P/2C Group Name Master IT Security User Level Mai

Page 109 - Port Configuration

NS2503-24P/2C User Manual 197 Group Name Master IT Security User Level Main Function Admin Viewer Admin Viewer Admin Viewer Aggregator S

Page 110

Copyright © 2013 UTC Fire & Security Americas Corporation, Inc. Interlogix is part of UTC Climate Controls & Security, a unit of Unite

Page 111 - DHCP Relay & Option 82

NS2503-24P/2C User Manual 20 Rack Mounting To install the Managed Switch in a 19-inch standard rack, please follows the instructions described below.

Page 112

NS2503-24P/2C User Manual 21 Installing the SFP transceiver This section describes how to plug-in an SFP transceiver into an SFP slot. The SFP transce

Page 113

NS2503-24P/2C User Manual 22 Before connecting the other switches, workstation or Media Converter: 1. Make sure both sides use the same SFP transcei

Page 114 - Per Port Configuration

NS2503-24P/2C User Manual 23 SWITCH MANAGEMENT This chapter explains the methods that you can use to configure management access to the Managed Switc

Page 115 - Access Control List

NS2503-24P/2C User Manual 24 Management Access Overview The Managed Switch gives you the flexibility to access and manage it using any or all of the f

Page 116

NS2503-24P/2C User Manual 25 Web Management The Managed Switch offers management features that allow users to manage the Managed Switch from anywhere

Page 117

NS2503-24P/2C User Manual 26 SNMP-Based Network Management You can use an external SNMP-based application to configure and manage the Managed Switc

Page 118 - Users Configuration

NS2503-24P/2C User Manual 27 Figure 3-5: Terminal Parameter Settings You can change these settings, if desired, after you log on. This management me

Page 119

NS2503-24P/2C User Manual 28Protocols The Managed Switch supports the following protocols:  Virtual terminal protocols, such as Telnet  Simple Ne

Page 120

NS2503-24P/2C User Manual 29 Web-Based Management This section introduces the configuration and functions of the Web-Based management. About Web-bas

Page 121 - MAC Limit

NS2503-24P/2C User Manual 3TABLE OF CONTENTS IFS NS2503-24P/2C USER MANUAL...

Page 122 - MAC Limit Port Status

NS2503-24P/2C User Manual 30 Requirements  The operating system of subscriber PC: Windows XP/2003, Vista, Windows 7, MAC OS X , Linux, Fedora, Ubun

Page 123 - 802.1X Configuration

NS2503-24P/2C User Manual 31 Figure 4-1-2: Web Main Page Screenshot 2. The Switch Menu on the left of the Web page let you access all the management

Page 124

NS2503-24P/2C User Manual 32 Main WEB PAGE The Managed Switch provides a Web-based browser interface for configuring and managing it. This interface a

Page 125 - System Configuration

NS2503-24P/2C User Manual 33 Figure 4-1-4: Managed Switch Main Functions Menu Screenshot

Page 126

NS2503-24P/2C User Manual 34System Use the System menu items to display and configure basic administrative details of the Managed Switch. Under Syste

Page 127 - 802.1x Port Configuration

NS2503-24P/2C User Manual 35 System Information In System information, it has two parts of setting – Basic and Misc Config. We will describe the confi

Page 128 - Misc Configuration

NS2503-24P/2C User Manual 36 Misc Config Choose Misc Config from System Information of Managed Switch, the screen in Figure 4-2-2 appears. Figure 4-

Page 129 - QoS Configuration

NS2503-24P/2C User Manual 37 The page includes the following fields: Object Description MAC Address Age-out Time Type the number of seconds that an i

Page 130

NS2503-24P/2C User Manual 38 IP Configuration The Managed Switch is a network device which needs to be assigned an IP address for being identified on

Page 131

NS2503-24P/2C User Manual 39The page includes the following fields: Object Description DHCP Enable or disable the DHCP client function. When DHCP

Page 132 - QoS PerPort Configuration

NS2503-24P/2C User Manual 4 SNMP Configuration...

Page 133 - TOS/DSCP

NS2503-24P/2C User Manual 40 Console Port Info The Managed Switch provide local console interface for switch command line management, console port inf

Page 134 - TOS/DSCP Port Configuration

NS2503-24P/2C User Manual 41SNMP Configuration SNMP Overview The Simple Network Management Protocol (SNMP) is an application layer protocol that fac

Page 135

NS2503-24P/2C User Manual 42 SNMP community An SNMP community is the group that devices and management stations running SNMP belong to. It helps defin

Page 136 - Power over Ethernet

NS2503-24P/2C User Manual 43 The page includes the following fields: Object Description Community Strings: Here you can define the new community str

Page 137

NS2503-24P/2C User Manual 44 Trap Managers A trap manager is a management station that receives the trap messages generated by the switch. If no trap

Page 138

NS2503-24P/2C User Manual 45The page includes the following fields: Object Description Group Name: A string identifying the group name that this en

Page 139

NS2503-24P/2C User Manual 46The page includes the following fields: Object Description View Name: A string identifying the view name that this entr

Page 140

NS2503-24P/2C User Manual 47The page includes the following fields: Object Description Group Name: A string identifying the group name that this en

Page 141 - PoE Schedule

NS2503-24P/2C User Manual 48SNMP V3 usm-user Configure SNMPv3 users table on this page. The entry index keys are Engine ID and User Name. The SNMPv3

Page 142

NS2503-24P/2C User Manual 49 Syslog Setting The Syslog Setting page allows you to configure the logging of messages that are sent to remote syslog ser

Page 143 - CONSOLE MANAGEMENT

NS2503-24P/2C User Manual 5 STP System Configuration ...

Page 144 - Configure IP address

NS2503-24P/2C User Manual 50System Log It provides the functions allowing the user to update the switch firmware via the Trivial File Transfer Protoc

Page 145

NS2503-24P/2C User Manual 51SNTP Setting Network Time Protocol (NTP) is a networking protocol for time synchronization between computer systems over

Page 146 - Commands Level

NS2503-24P/2C User Manual 52Firmware Upgrade It provides the functions allowing the user to update the switch firmware via the Trivial File Transfer

Page 147 - COMMAND LINE INTERFACE

NS2503-24P/2C User Manual 53 HTTP Firmware Upgrade The HTTP Firmware Upgrade page contains fields for downloading system image files from the Local Fi

Page 148 - System Commands

NS2503-24P/2C User Manual 54 Configuration Backup TFTP Restore Configuration You can restore a previous backup configuration from the TFTP server t

Page 149 - Switch Static Configuration

NS2503-24P/2C User Manual 55 TFTP Backup Configuration You can back up the current configuration from flash ROM to the TFTP server for the purpose of

Page 150

NS2503-24P/2C User Manual 56 Factory Default Reset switch to default configuration. Click the RESET button to reset all configurations to the default

Page 151

NS2503-24P/2C User Manual 57 Port Configuration Use the Port Configuration Menu to display or configure the Managed Switch's ports. This section

Page 152 - Trunk Configuration

NS2503-24P/2C User Manual 58 The page includes the following fields: Object Description Port: Use the scroll bar and click on the port number to choo

Page 153

NS2503-24P/2C User Manual 59 Rate Control This page provides rate control on each port - it contains Ingress and Egress items and the unit is 128Kbps.

Page 154 - VLAN Configuration

NS2503-24P/2C User Manual 6 Advanced 802.1Q VLAN Configuration...

Page 155 - VLAN Mode: Port-based

NS2503-24P/2C User Manual 60 Port Status This page displays current port configurations and operating status. Via the summary table, status of each po

Page 156

NS2503-24P/2C User Manual 61Port Statistics The following chart provides the current statistic information which displays the real-time packet transf

Page 157

NS2503-24P/2C User Manual 62 Port Sniffer The Port Sniffer (mirroring) is a method for monitor traffic in switched networks. Traffic through a port ca

Page 158

NS2503-24P/2C User Manual 63 Figure 4-3-6: Port Sniffer Interface Screenshot The page includes the following fields: Object Description Sniffer Type

Page 159 - Administration Configuration

NS2503-24P/2C User Manual 64 Protect Port There are two protected port groups; ports in different groups can't communicate. In the same group, pr

Page 160 - IP Configuration

NS2503-24P/2C User Manual 65 Remote Ping The Remote Ping allows user to check the device connection status via the ping function. Figure 4-3-8: Remot

Page 161 - TFTP Update Firmware

NS2503-24P/2C User Manual 66 VLAN configuration VLAN Overview A Virtual Local Area Network (VLAN) is a network topology configured according to a lo

Page 162 - MAC limit

NS2503-24P/2C User Manual 67 802.1Q Tag User Priority CFI VLAN ID (VID) 3 bits 1 bits 12 bits TPID (Tag Protocol Identifier) TCI (Tag Control

Page 163 - Port Mirroring Configuration

NS2503-24P/2C User Manual 68 Static VLAN Configuration A Virtual LAN (VLAN) is a logical network grouping that limits the broadcast domain. It allows

Page 164 - Quality of Service

NS2503-24P/2C User Manual 69 Port-based VLAN Packets can go among only members of the same VLAN group. Note all unselected ports are treated as belong

Page 165 - MAC Address Configuration

NS2503-24P/2C User Manual 7 POWER OVER ETHERNET OVERVIEW...189 What is PoE? ...

Page 166

NS2503-24P/2C User Manual 70 By adding ports to the VLAN you have created one port-based VLAN group completely. Figure 4-4-3: Static VLAN Interface

Page 167 - STP/MSTP Commands

NS2503-24P/2C User Manual 71 802.1Q VLAN Tagged-based VLAN is an IEEE 802.1Q specification standard. Therefore, it is possible to create a VLAN across

Page 168

NS2503-24P/2C User Manual 72 VLAN Group Configuration  VLAN Group Configuration Figure 4-4-4: VLAN Group Configuration Interface Screenshot 1. C

Page 169

NS2503-24P/2C User Manual 73 Figure 4-4-5: VLAN Group Configuration Interface Screenshot 5. Select specific port as member port and the screen in F

Page 170

NS2503-24P/2C User Manual 74 Figure 4-4-6: 802.1Q VLAN Setting Interface Screenshot The page includes the following fields: Object Description VLAN

Page 171

NS2503-24P/2C User Manual 75 VLAN Filter  802.1Q VLAN Port Configuration This page is used for configuring the Switch port VLAN. The VLAN per Port C

Page 172 - Community Strings

NS2503-24P/2C User Manual 76 The page includes the following fields: Object Description NO Indicate port 1 to port 10. PVID Set the port VLAN ID that

Page 173 - Trap Managers

NS2503-24P/2C User Manual 77 GVRP Setting To configure GVRP Enable global GVRP function: select GVRP enable "Enable". Enable port GVRP func

Page 174

NS2503-24P/2C User Manual 78 GVRP Table The GVRP Table can be used to display dynamic VLANs from being learned via GVRP. Figure 4-4-9: GVRP Table

Page 175 - 802.1x Protocol

NS2503-24P/2C User Manual 79 Q-in-Q VLAN IEEE 802.1Q Tunneling (Q-in-Q) IEEE 802.1Q Tunneling (QinQ) is designed for service providers carrying tra

Page 176

NS2503-24P/2C User Manual 8 Introduction The IFS Layer 2 Managed Switch NS2503-24P/2C has 24 10/100Mbps 802.3at compliant PoE ports, with two Gigabi

Page 177

NS2503-24P/2C User Manual 80 Q-in-Q Port Setting The QinQ VLAN \ QinQ Port Setting screen in Figure 4-4-10 appears. Figure 4-4-10: Q-in-Q Port Setti

Page 178 - Non-Ipv4 ACL commands

NS2503-24P/2C User Manual 81 Q-in-Q Tunnel Setting Business customers of service providers often have specific requirements for VLAN IDs and the numbe

Page 179 - Binding

NS2503-24P/2C User Manual 82 Trunking Port trunking is the combination of several ports or network cables to expand the connection speed beyond the li

Page 180 - Power over Ethernet Commands

NS2503-24P/2C User Manual 83 Aggregator setting This section provides Port Trunk-Aggregator Setting of each port from the Managed Switch, the screen i

Page 181

NS2503-24P/2C User Manual 84 Work ports: This column field allows the user to type in the total number of active port up to four. With LACP static tru

Page 182 - Configure PoE -- System

NS2503-24P/2C User Manual 85 Figure 4-5-3: Static Trunking Group Information Screenshot The page includes the following fields: Object Description

Page 183

NS2503-24P/2C User Manual 86 Figure 4-5-4: Aggregation Information of Switch 1 Screenshot 5. Click on the tab of Aggregator Information to check th

Page 184

NS2503-24P/2C User Manual 87 Figure 4-5-5: Switch 2 Configuration Interface Screenshot 5. Click on the tab of Aggregator Information to check the t

Page 185 - Configure PoE -- Port

NS2503-24P/2C User Manual 88 State Activity Having the set up the LACP aggregator the tab of Aggregator Setting, you can configure the state activity

Page 186 - (config)# poe priority low 1

NS2503-24P/2C User Manual 89 Forwarding and Filtering The frames of Ethernet Packets contain a MAC address (SMAC address), which shows the MAC address

Page 187

NS2503-24P/2C User Manual 9 Cost-effective solution with SNMP monitor for Network deployment Not only for catering to the need of easy WEB-based man

Page 188 - SWITCH OPERATION

NS2503-24P/2C User Manual 90 Static MAC Table You can add a static MAC address that remains in the switch's address table regardless of whether t

Page 189 - POWER OVER ETHERNET OVERVIEW

NS2503-24P/2C User Manual 91 MAC Filtering By filtering MAC address, the switch can easily filter the pre-configured MAC address and reduce the un-saf

Page 190 - The PoE Provision Process

NS2503-24P/2C User Manual 92 IGMP Snooping Theory The Internet Group Management Protocol (IGMP) lets host and routers share information about multica

Page 191

NS2503-24P/2C User Manual 93 Figure 4-7-2: Multicast Flooding Figure 4-7-3: IGMP Snooping Multicast Stream Control

Page 192

NS2503-24P/2C User Manual 94 IGMP Versions 1 and 2 Multicast groups allow members to join or leave at any time. IGMP provides the method for members a

Page 193 - TROUBLE SHOOTING

NS2503-24P/2C User Manual 95 Figure 4-7-4: IGMP State Transitions  IGMP Querier A router, or multicast-enabled switch, can periodically ask thei

Page 194 - 10/100Mbps, 10/100Base-TX

NS2503-24P/2C User Manual 96 IGMP Configuration The Managed Switch support IP multicast, can enable IGMP protocol on web management’s switch setting a

Page 195

NS2503-24P/2C User Manual 97 IGMP Fast leave: Enable or disable Fast Leave on the port. IGMP Querier: Enable or disable the IGMP query function. The I

Page 196

NS2503-24P/2C User Manual 98 Static Multicast Table Static Multicast Table is a feature for user to force steaming multicast stream to indicate port.

Page 197

NS2503-24P/2C User Manual 99 The page includes the following fields: Object Description IP Address: Allows user to input multicast address group. A

Comments to this Manuals

No comments