Figure 4-16-7: LLDP PoE Neighbour Screenshot
Please be noticed that administrator has to enable LLDP port from LLDP configuration, please refer to following example (The
screen in Figure 4-16-8 appears.) we enabled LLDP function from port1 ro port3, administrator has to plug a PD that supported
PoE LLDP function, and then administrator is going to see the PoE information of the PD form LLDP.
Figure 4-16-8: LLDP Configuration Screenshot
4.16.9 PoE Alive Check Configuration
The PoE Switch can be configured to monitor connected PD’s status in real-time via ping action. Once the PD stops working and
without response, the PoE Switch is going to restart PoE port port power, and bring the PD back to work. It will greatly enhance
the reliability and reduces administrator management burden.